News
-
Precautions when using defibrillator electrodes
Note the following when using defibrillator electrodes to ensure safety and effectiveness: 1. Place the device in the correct position • Adults: The anterolateral position is adopted by default, that is, one piece is attached below the right clavicle (right margin of the sternum) and the other i...Read more -
What are the ECG electrodes?
When it comes to monitoring the electrical activity of the heart, an electrocardiogram (ECG) is an important diagnostic tool. ECG electrodes play a vital role in this process, but what exactly are they and how do they work? ECG electrodes are small, sticky patches that are placed in specific loca...Read more -
How to proper use of negative plate?
1. The negative plate should be selected where the blood vessels are rich and closest to the muscle of the surgical site (recommended in the upper arm and thigh of the artery). 2. It is best to shave the hair and then use alcohol to remove grease and dander on the skin, etc., to be wiped dry and...Read more -
Structure and principle of TENS electrodes
1. Structural composition of the TENS electrodes pad The structure of the treatment electrode sheet may seem simple, but it is actually composed of multiple layers of material, ensuring good electrical conductivity, comfort and durability. In general, the physiotherapy electrode is composed of th...Read more -
Düsseldorf Medical Devices Exhibition (MEDICA)
The Düsseldorf Medical Devices Exhibition (MEDICA) is the world’s largest and most authoritative hospital and medical device exhibition. It ranks first in the world’s medical trade exhibitions with its irreplaceable scale and influence. It is held every year in Düsseldorf, Germany, sh...Read more -
Why do high frequency electroknives stick negative plates?
When the high-frequency electrotome is used, it is usually necessary to apply a negative electrode plate on the patient. The negative electrode plate is also called the electrode plate and the loop plate. It plays a role in recovering the high-frequency current during the operation. In addition, ...Read more -
Where should the Defibrillation Electrodes pad be placed?
Defibrillation Electrodes pad is to shock the heart with an electric current, and the rescue method to terminate ventricular fibrillation, usually there are two kinds of electric shock defibrillation electrode plate placement position. The specific analysis is as follows: 1. Precordial placement:...Read more -
Welcome to the 90th China International Medical Device Expo
2024 CMEF The 90th China International Medical Device Exhibition (Shenzhen Autumn Exhibition) is held by Reed Sinoptila, twice a year. Shenzhen Autumn Fair will be held in Shenzhen International Convention and Exhibition Center from October 12 to 15, 2024, with an estimated exhibition area of 240...Read more -
The use of TENS electrodes pad
TENS electrodes pad - A common physical therapy method,mainly using low-frequency current through the body surface electrode conduction to human tissue, produce a certain biological effect, in order to achieve the purpose of treatment and improvement of disease symptoms. The body surface electrod...Read more -
Quanding Medical Participated in the Shanghai CMEF Exhibition
In 2023,Quanding Medical ushered in a new year of CMEF Spring International Medical Exhibition. The venue of this exhibition is in Shanghai, China, and the time is from May 14th to May 17th. Quanding Medical has a brand-new and exquisitely decorated booth this time, covering an area of two stan...Read more -
Surgical electric blade replacement
Standardize the operating procedures of unipolar electrotome, bipolar electrocoagulation, ultrasonic knife and electrosurgical energy equipment -- guide the operating room nurses to correctly evaluate, use and maintain the electrosurgical equipment, reduce the safety ris...Read more -
Disposable neutral electrode connection REM cable
Disposable neutral electrode connection wire is also called neutral electrode plate connection wire, high frequency electric knife negative plate connection wire, the length of the line is 3 meters, PVC skin material, built-in thick copper wire, longer service life, fixt...Read more